Detectable Object
Conductors and dielectrics
Differential Travel
4% to 20% of sensing distance
E2K-X15ME Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X15ME Ambient Temperature Range
Operating/Storage: -25 to 70°C (with no icing or condensation)
E2K-X15ME Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X15ME Current Consumption
E2K-X15ME Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X15ME Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X15ME Indicators
Detection indicator (red)
E2K-X15ME Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X15ME Materials Clamping Nuts
E2K-X15ME Power Supply Voltage
12 to 24 VDC (10 to 30 VDC)
E2K-X15ME Protection Circuits
Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polarity protection
E2K-X15ME Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2K-X15ME Response Frequency
E2K-X15ME Sensing Distance
E2K-X15ME Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X15ME Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X15ME Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X15ME Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±20%
E2K-X15MY Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X15MY Ambient Temperature Range
Operating/Storage: -10 to 55°C (with no icing or condensation)
E2K-X15MY Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X15MY Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X15MY Dielectric Strength
2,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X15MY Indicators
Operation indicator (red)
E2K-X15MY Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X15MY Leakage Current
E2K-X15MY Materials Clamping Nuts
E2K-X15MY Power Supply Voltage
100 to 220 VAC (90 to 250 VAC)
E2K-X15MY Protection Circuits
E2K-X15MY Response Frequency
E2K-X15MY Sensing Distance
E2K-X15MY Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X15MY Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X15MY Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X15MY Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±10%
E2K-X4ME Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X4ME Ambient Temperature Range
Operating/Storage: -25 to 70°C (with no icing or condensation)
E2K-X4ME Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X4ME Current Consumption
E2K-X4ME Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X4ME Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X4ME Indicators
Detection indicator (red)
E2K-X4ME Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X4ME Materials Clamping Nuts
E2K-X4ME Power Supply Voltage
12 to 24 VDC (10 to 30 VDC)
E2K-X4ME Protection Circuits
Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polarity protection
E2K-X4ME Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2K-X4ME Response Frequency
E2K-X4ME Sensing Distance
E2K-X4ME Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X4ME Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X4ME Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X4ME Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±20%
E2K-X4MY Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X4MY Ambient Temperature Range
Operating/Storage: -10 to 55°C (with no icing or condensation)
E2K-X4MY Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X4MY Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X4MY Dielectric Strength
2,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X4MY Indicators
Operation indicator (red)
E2K-X4MY Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X4MY Materials Clamping Nuts
E2K-X4MY Power Supply Voltage
100 to 220 VAC (90 to 250 VAC)
E2K-X4MY Protection Circuits
E2K-X4MY Response Frequency
E2K-X4MY Sensing Distance
E2K-X4MY Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X4MY Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X4MY Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X4MY Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±10%
E2K-X8ME Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X8ME Ambient Temperature Range
Operating/Storage: -25 to 70°C (with no icing or condensation)
E2K-X8ME Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X8ME Current Consumption
E2K-X8ME Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X8ME Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X8ME Indicators
Detection indicator (red)
E2K-X8ME Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X8ME Materials Clamping Nuts
E2K-X8ME Power Supply Voltage
12 to 24 VDC (10 to 30 VDC)
E2K-X8ME Protection Circuits
Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polarity protection
E2K-X8ME Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2K-X8ME Response Frequency
E2K-X8ME Sensing Distance
E2K-X8ME Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X8ME Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X8ME Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X8ME Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±20%
E2K-X8MY Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
E2K-X8MY Ambient Temperature Range
Operating/Storage: -10 to 55°C (with no icing or condensation)
E2K-X8MY Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-X8MY Degree Of Protection
IP66 (IEC), in-house standards: oil-resistant
E2K-X8MY Dielectric Strength
2,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2K-X8MY Indicators
Operation indicator (red)
E2K-X8MY Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
E2K-X8MY Materials Clamping Nuts
E2K-X8MY Power Supply Voltage
100 to 220 VAC (90 to 250 VAC)
E2K-X8MY Protection Circuits
E2K-X8MY Response Frequency
E2K-X8MY Sensing Distance
E2K-X8MY Shock Resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
E2K-X8MY Temperature Influence
±20% max. of sensing distance at 23°C in the operating temperature range
E2K-X8MY Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
E2K-X8MY Voltage Influence
±2% max. of sensing distance at rated voltage at rated voltage ±10%
Standard Sensing Object
Grounded metal plate: 50 × 50 × 1 mm