A Series Electrical Setup
Single stage (AYP Models) & Dual stage (AYT Models)
A Series Max Voltage
440 VAC Phase to Phase; 250 VAC Phase to Neutral / Ground
A Series Mounting Features
A Series Termination Inputs
A Series Termination Outputs
AFC Series Current Ratings
AFC Series Electrical Setup
Not specified in document
AFC Series Leakage Current
Not specified in document
AFC Series Mounting Features
AFC Series Termination Inputs
AFC Series Termination Outputs
AFD Series Current Ratings
AFD Series Electrical Setup
Not specified in document
AFD Series Leakage Current
Not specified in document
AFD Series Mounting Features
AFD Series Termination Inputs
AFD Series Termination Outputs
AQ Series Current Ratings
AQ Series Electrical Setup
AQ Series Leakage Current
1.2mA / 2.3mA (3A models); .7mA / 1.2mA (6A models)
AQ Series Mounting Features
Screw mounting (flange or panel)
AQ Series Termination Inputs
AQ Series Termination Outputs
AYA Series Current Ratings
16, 25, 36, 50, 63 & 100A
AYA Series Electrical Setup
AYA Series Leakage Current
AYA Series Max Voltage
440 VAC Phase to Phase; 250 VAC Phase to Neutral / Ground
AYA Series Mounting Features
Screw mounting (flange or inserts)
AYA Series Termination Inputs
Terminal bolt & nut or DIN type terminals
AYA Series Termination Outputs
Terminal bolt & nut or DIN type terminals
AYO Series Current Ratings
AYO Series Electrical Setup
AYO Series Leakage Current
2.0mA / 3.0mA (3 - 10A models); 3.5mA / 5.5mA (20A models)
AYO Series Max Voltage
440 VAC Phase to Phase; 250 VAC Phase to Neutral / Ground
AYO Series Mounting Features
Screw mounting (flange or panel)
AYO Series Termination Inputs
.25 [6.3] spade terminals
AYO Series Termination Outputs
.25 [6.3] spade terminals
B Series Current Ratings
1, 2, 3, 5, 10, 20 or 30A
B Series Electrical Setup
B Series Leakage Current
VB Models: .4mA / .7mA; EB Models: .21mA / .36mA
B Series Mounting Features
B Series Termination Inputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
B Series Termination Outputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
DA Series Current Ratings
3, 6, 10 & 15A (DA Series); 15, 30, 60, 100 & 125A (DA Series)
DA Series Electrical Setup
Not specified in document
DA Series Leakage Current
Not specified in document
DA Series Max Voltage
125 VDC (DA, DB) & 80VDC (DC, P)
DA Series Mounting Features
DA Series Termination Inputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DA Series Termination Outputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DB Series Current Ratings
DB Series Electrical Setup
Not specified in document
DB Series Leakage Current
Not specified in document
DB Series Max Voltage
125 VDC (DA, DB) & 80VDC (DC, P)
DB Series Mounting Features
DB Series Termination Inputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DB Series Termination Outputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DC Series Current Ratings
DC Series Electrical Setup
Not specified in document
DC Series Leakage Current
Not specified in document
DC Series Max Voltage
125 VDC (DA, DB) & 80VDC (DC, P)
DC Series Mounting Features
DC Series Termination Inputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DC Series Termination Outputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DCP Series Current Ratings
DCP Series Electrical Setup
Not specified in document
DCP Series Leakage Current
Not specified in document
DCP Series Max Voltage
125 VDC (DA, DB) & 80VDC (DC, P)
DCP Series Mounting Features
DCP Series Termination Inputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DCP Series Termination Outputs
Spade terminals, PCB pins, wire leads, DA or DCB connector, or terminal bolt & nut
DK Series Current Ratings
DK Series Electrical Setup
DK Series Leakage Current
VDK Models: .4mA / .7mA; EDK Models: .22mA / .38mA
DK Series Mounting Features
DK Series Termination Inputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
DK Series Termination Outputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
EBP Series Current Ratings
EBP Series Electrical Setup
EBP Series Leakage Current
EBP Models: .13mA / .21mA
EBP Series Mounting Features
EBP Series Termination Inputs
PCB pins .025 [.635] square or RAST 5 header interface
EBP Series Termination Outputs
PCB pins .025 [.635] square or RAST 5 header interface
EDP Series Current Ratings
EDP Series Electrical Setup
EDP Series Leakage Current
EDP Models: .22mA / .38mA
EDP Series Mounting Features
EDP Series Termination Inputs
PCB pins .025 [.635] square or RAST 5 header interface
EDP Series Termination Outputs
PCB pins .025 [.635] square or RAST 5 header interface
EMC Series Current Ratings
EMC Series Electrical Setup
EMC Series Leakage Current
.21mA / .43mA (3-10A models); .73mA / 1.52mA (15-30A models)
EMC Series Mounting Features
EMC Series Termination Inputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
EMC Series Termination Outputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
EOP Series Current Ratings
EOP Series Electrical Setup
EOP Series Leakage Current
EOP Models: .22mA / .38mA
EOP Series Mounting Features
EOP Series Termination Inputs
PCB pins .025 [.635] square or RAST 5 header interface
EOP Series Termination Outputs
PCB pins .025 [.635] square or RAST 5 header interface
EP Series Current Ratings
EP Series Electrical Setup
EP Series Leakage Current
.21mA / .36mA (EP models)
EP Series Mounting Features
Screw mounting (flange or panel)
EP Series Termination Inputs
.25 [6.3] spade terminals, wire leads, terminal bolt & nut, or IEC 60320-1 C14
EP Series Termination Outputs
.25 [6.3] spade terminals, wire leads, or terminal bolt & nut
FC Series Current Ratings
FC Series Electrical Setup
Single stage (B suffix); Dual stage (no suffix)
FC Series Leakage Current
3.9mA / 7.0mA (B suffix, single stage); 3.8mA / 6.7mA (no suffix, dual stage)
FC Series Mounting Features
FC Series Termination Inputs
.25 [6.3] spade terminals, wire leads, terminal bolt & nut, or IEC 60320-1 C14
FC Series Termination Outputs
.25 [6.3] spade terminals, wire leads, or terminal bolt & nut
FFA Series Current Ratings
FFA Series Electrical Setup
Not specified in document
FFA Series Leakage Current
Not specified in document
FFA Series Mounting Features
FFA Series Termination Inputs
FFA Series Termination Outputs
FFD Series Current Ratings
FFD Series Electrical Setup
Not specified in document
FFD Series Leakage Current
Not specified in document
FFD Series Mounting Features
FFD Series Termination Inputs
FFD Series Termination Outputs
G Series Electrical Setup
Single stage (6A models); Dual stage (10A models)
G Series Leakage Current
.3mA / .5mA (EG models); 1.2mA / 2.0mA (VG & N models)
G Series Mounting Features
G Series Termination Inputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
G Series Termination Outputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
IK Series Current Ratings
IK Series Electrical Setup
Dual stage (6-80A models)
IK Series Leakage Current
.06mA / 1.2mA* (1 & 6A models); 1.7mA / 3.2mA* (16 - 50A models); 5.2mA / 9.9mA* (80A model)
IK Series Max Voltage
500 VAC MAX. Line to Ground
IK Series Mounting Features
IK Series Termination Inputs
.25 [6.3] spade terminals or DIN type terminal block and bolt/nut
IK Series Termination Outputs
.25 [6.3] spade terminals or DIN type terminal block and bolt/nut
K Series Current Ratings
1, 2, 3, 5, 10, 20, 30, 40 or 60A
K Series Electrical Setup
K Series Leakage Current
VK Models: .5mA / 1.0mA; EK Models: .21mA / .36mA
K Series Mounting Features
Screw mounting (flange or panel)
K Series Termination Inputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut, wire leads or IEC 60320-1 C14 or C20
K Series Termination Outputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
N Series Electrical Setup
Single stage (6A models); Dual stage (10A models)
N Series Leakage Current
.3mA / .5mA (EG models); 1.2mA / 2.0mA (VG & N models)
N Series Mounting Features
N Series Termination Inputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
N Series Termination Outputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
Q Series Electrical Setup
Dual stage (medical versions without y-capacitors)
Q Series Leakage Current
.73mA / 1.27mA (3 & 20A VQ models); .22mA / .38mA (3 & 20A EQ models); .29mA / .51mA (6A EQ models)
Q Series Mounting Features
Screw mounting (flange or panel)
Q Series Termination Inputs
.25 [6.3] spade terminals, DIN type terminals, wire leads or IEC 60320-1 C14
Q Series Termination Outputs
.25 [6.3] spade terminals or DIN type terminals, wire leads
R Series Electrical Setup
R Series Leakage Current
VR Models: .4mA / .7mA; ER Models: .21mA / .36mA
R Series Mounting Features
Screw mounting (flange or panel)
R Series Termination Inputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut, wire leads or IEC 60320-1 C14
R Series Termination Outputs
.25 [6.3] spade terminals, 8-32 terminal bolt & nut or wire leads
RK Series Current Ratings
RK Series Electrical Setup
RK Series Leakage Current
RK Series Mounting Features
RK Series Termination Inputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
RK Series Termination Outputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
S Series Current Ratings
3, 6, 10, 20 & 60A (60A S Series only)
S Series Electrical Setup
S Series Leakage Current
.4mA / .7mA (S Series 3-10A); .75mA / 1.25mA (S Series 60A)
S Series Mounting Features
S Series Termination Inputs
.25 [6.3] spade terminals or terminal bolt & nut
S Series Termination Outputs
.25 [6.3] spade terminals or terminal bolt & nut
SB Series Current Ratings
SB Series Electrical Setup
SB Series Leakage Current
.75mA / 1.25mA (VSB models); .22mA / .36mA (ESB models)
SB Series Mounting Features
SB Series Termination Inputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
SB Series Termination Outputs
.25 [6.3] spade terminals or 8-32 terminal bolt & nut
SK Series Current Ratings
SK Series Electrical Setup
Single stage; Dual stage + ground choke (1A only)
SK Series Leakage Current
.4mA / .7mA (3-10A VSK models); .21mA / .36mA (3-10A ESK models); .75mA / 1.25mA (3-10A VSK models); .3mA / .5mA (3-10A ESK models)
SK Series Mounting Features
Screw mounting (flange or panel)
SK Series Termination Inputs
.25 [6.3] spade terminals, terminal bolt & nut, wire leads or IEC 60320-1 C14
SK Series Termination Outputs
.25 [6.3] spade terminals, terminal bolt & nut or wire leads
T Series Electrical Setup
Single (3-10A) & Dual stage (10-20A) (medical versions without y-capacitors)
T Series Leakage Current
.3mA / .5mA (ET models); .75mA / 1.2mA (VT models)
T Series Mounting Features
T Series Termination Inputs
.25 [6.3] spade terminals, wire leads, terminal bolt & nut, or IEC 60320-1 C14
T Series Termination Outputs
.25 [6.3] spade terminals, wire leads, or terminal bolt & nut
V Series Current Ratings
3, 6, 10, 20 & 60A (60A S Series only)
V Series Electrical Setup
V Series Leakage Current
.5mA / .82mA (V & W Series)
V Series Mounting Features
V Series Termination Inputs
.25 [6.3] spade terminals or terminal bolt & nut
V Series Termination Outputs
.25 [6.3] spade terminals or terminal bolt & nut
VP Series Current Ratings
VP Series Electrical Setup
VP Series Leakage Current
.73mA / 1.27mA (VP models)
VP Series Mounting Features
Screw mounting (flange or panel)
VP Series Termination Inputs
.25 [6.3] spade terminals, wire leads, terminal bolt & nut, or IEC 60320-1 C14
VP Series Termination Outputs
.25 [6.3] spade terminals, wire leads, or terminal bolt & nut
W Series Current Ratings
3, 6, 10, 20 & 60A (60A S Series only)
W Series Electrical Setup
W Series Leakage Current
.5mA / .82mA (V & W Series)
W Series Mounting Features
W Series Termination Inputs
.25 [6.3] spade terminals or terminal bolt & nut
W Series Termination Outputs
.25 [6.3] spade terminals or terminal bolt & nut
WG Series Current Ratings
WG Series Electrical Setup
WG Series Leakage Current
A, B & C Models: .76mA / 1.27mA; D, E & F Models: .10mA / .20mA
WG Series Mounting Features
WG Series Termination Inputs
.25 [6.3] spade terminals, .025 [.635] square or .065[1.65] diagonal
WG Series Termination Outputs
.25 [6.3] spade terminals, .025 [.635] square or .065[1.65] diagonal
X Series Electrical Setup
X Series Mounting Features
Screw mount or PC board pins
X Series Termination Inputs
.25 [6.3] spade terminals or PCB pins
X Series Termination Outputs
.25 [6.3] spade terminals or PCB pins
Y Series Electrical Setup
Y Series Mounting Features
Screw mount or PC board pins
Y Series Termination Inputs
.25 [6.3] spade terminals or PCB pins
Y Series Termination Outputs
.25 [6.3] spade terminals or PCB pins
Z Series Electrical Setup
Z Series Mounting Features
Screw mount or PC board pins
Z Series Termination Inputs
.25 [6.3] spade terminals or PCB pins
Z Series Termination Outputs
.25 [6.3] spade terminals or PCB pins