Common Connection Method
Pre-wired (Standard length: 2 m), M12 4-pin connector, M8 3-pin connector
Common Current Consumption
Common Dielectric Strength
1,000 VAC at 50/60Hz for 1 min
Common Indicator
Operation indicator (Yellow LED)
Common Insulation Resistance
Common Material Case
Brass-nickel plated (M8 Stainless steel or brass-nickel plated)
Common Material Clamping Nut
Common Material Sensing Surface
Common Operating Temperature Max
Common Operating Temperature Min
Common Output Type
PNP open collector or NPN open collector
Common Power Supply Voltage
12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
Common Protection Circuit
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
Common Storage Temperature Max
Common Storage Temperature Min
Common Temperature Influence
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C; ±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
Common Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Common Voltage Influence
±1% max. of sensing distance in rated voltage range ±15%
M12 Non-shielded Differential Travel
10% max. of sensing distance
M12 Non-shielded Response Frequency
M12 Non-shielded Sensing Distance
M12 Non-shielded Setting Distance
M12 Non-shielded Shock Resistance
1,000 m/s2, 10 times each in X, Y and Z directions
M12 Non-shielded Standard Target
M12 Non-shielded Weight M12 Connector
M12 Non-shielded Weight Pre-wired
M12 Shielded Differential Travel
10% max. of sensing distance
M12 Shielded Response Frequency
M12 Shielded Sensing Distance
M12 Shielded Setting Distance
M12 Shielded Shock Resistance
500 m/s2, 10 times each in X, Y and Z directions
M12 Shielded Standard Target
M12 Shielded Weight M12 Connector
M12 Shielded Weight Pre-wired
M18 Non-shielded Differential Travel
10% max. of sensing distance
M18 Non-shielded Response Frequency
M18 Non-shielded Sensing Distance
M18 Non-shielded Setting Distance
M18 Non-shielded Shock Resistance
1,000 m/s2, 10 times each in X, Y and Z directions
M18 Non-shielded Standard Target
M18 Non-shielded Weight M12 Connector
M18 Non-shielded Weight Pre-wired
M18 Shielded Differential Travel
10% max. of sensing distance
M18 Shielded Response Frequency
M18 Shielded Sensing Distance
M18 Shielded Setting Distance
M18 Shielded Shock Resistance
500 m/s2, 10 times each in X, Y and Z directions
M18 Shielded Standard Target
M18 Shielded Weight M12 Connector
M18 Shielded Weight Pre-wired
M30 Non-shielded 20mm Differential Travel
10% max. of sensing distance
M30 Non-shielded 20mm Response Frequency
M30 Non-shielded 20mm Sensing Distance
M30 Non-shielded 20mm Setting Distance
M30 Non-shielded 20mm Standard Target
M30 Non-shielded 20mm Weight M12 Connector
M30 Non-shielded 20mm Weight Pre-wired
M30 Non-shielded 30mm Differential Travel
10% max. of sensing distance
M30 Non-shielded 30mm Response Frequency
M30 Non-shielded 30mm Sensing Distance
M30 Non-shielded 30mm Setting Distance
M30 Non-shielded 30mm Standard Target
M30 Non-shielded 30mm Weight M12 Connector
M30 Non-shielded 30mm Weight Pre-wired
M30 Non-shielded Shock Resistance
1,000 m/s2, 10 times each in X, Y and Z directions
M30 Shielded Differential Travel
10% max. of sensing distance
M30 Shielded Response Frequency
M30 Shielded Sensing Distance
M30 Shielded Setting Distance
M30 Shielded Shock Resistance
500 m/s2, 10 times each in X, Y and Z directions
M30 Shielded Standard Target
M30 Shielded Weight M12 Connector
M30 Shielded Weight Pre-wired
M8 Non-shielded Differential Travel
10% max. of sensing distance
M8 Non-shielded Response Frequency
M8 Non-shielded Sensing Distance
M8 Non-shielded Setting Distance
M8 Non-shielded Standard Target
M8 Shielded Ambient Humidity
M8 Shielded Connection Method
Pre-wired (2 m), M12 connector, M8 connector
M8 Shielded Current Consumption
M8 Shielded Dielectric Strength
1,000 VAC at 50/60Hz for 1 min
M8 Shielded Differential Travel
10% max. of sensing distance
M8 Shielded Indicator
Operation indicator (Yellow LED)
M8 Shielded Insulation Resistance
M8 Shielded Material Cable
M8 Shielded Material Case
Stainless steel or brass-nickel plated
M8 Shielded Material Clamping Nut
M8 Shielded Material Sensing Surface
M8 Shielded Operating Temperature Max
M8 Shielded Operating Temperature Min
M8 Shielded Operation Mode
M8 Shielded Output Type
PNP open collector or NPN open collector
M8 Shielded Power Supply Voltage
12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC)
M8 Shielded Protection Circuit
Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection
M8 Shielded Protection Rating
M8 Shielded Residual Voltage
M8 Shielded Response Frequency
M8 Shielded Sensing Distance
M8 Shielded Setting Distance
M8 Shielded Shock Resistance
500 m/s2, 10 times each in X, Y and Z directions
M8 Shielded Standard Target
M8 Shielded Storage Temperature Max
M8 Shielded Storage Temperature Min
M8 Shielded Temperature Influence
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C; ±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C
M8 Shielded Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
M8 Shielded Voltage Influence
±1% max. of sensing distance in rated voltage range ±15%
M8 Shielded Weight M12 Connector
M8 Shielded Weight M8 Connector
M8 Shielded Weight Pre-wired