Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric Strength
1,000 VAC, 50/60Hz for 1 minute between current-carrying parts and case
Degree Of Protection
IEC 60529 IP67, in-house standards: oil-resistant
Vibration Resistance
Destruction: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock Resistance
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Connection Method
Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models
Ambient Humidity Range
35% to 95% (with no condensation)
Ambient Temperature Range
0 to 50°C (with no icing or condensation)
Detectable Object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 4.)
Differential Travel
20% max. of sensing distance
E2EZ-X2D Current Consumption
E2EZ-X2D Indicators
D1 Models: Operation indicator (red), Setting indicator (green); D2 Models: Operation indicator (red)
E2EZ-X2D Operation Mode
D1 Models: NO; D2 Models: NC
E2EZ-X2D Protection Circuits
Load short-circuit protection, Surge suppressor
E2EZ-X2D Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EZ-X2D Response Frequency
E2EZ-X2D Sensing Distance
E2EZ-X2D Standard Sensing Object
E2EZ-X4B1 Current Consumption
E2EZ-X4B1 Indicators
Detection indicator (red)
E2EZ-X4B1 Leakage Current
E2EZ-X4B1 Load Current
100mA max. at 12 VDC (30 VDC max.) and 200mA max. at 24 VDC (30 VDC max.)
E2EZ-X4B1 Operation Mode
NO (with sensing object approaching)
E2EZ-X4B1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2EZ-X4B1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2EZ-X4B1 Response Frequency
E2EZ-X4B1 Sensing Distance
E2EZ-X4B1 Standard Sensing Object
E2EZ-X4C1 Current Consumption
E2EZ-X4C1 Indicators
Detection indicator (red)
E2EZ-X4C1 Leakage Current
E2EZ-X4C1 Load Current
100mA max. at 12 VDC (30 VDC max.) and 200mA max. at 24 VDC (30 VDC max.)
E2EZ-X4C1 Operation Mode
NO (with sensing object approaching)
E2EZ-X4C1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2EZ-X4C1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2EZ-X4C1 Response Frequency
E2EZ-X4C1 Sensing Distance
E2EZ-X4C1 Standard Sensing Object
E2EZ-X4D Current Consumption
E2EZ-X4D Indicators
D1 Models: Operation indicator (red), Setting indicator (green); D2 Models: Operation indicator (red)
E2EZ-X4D Operation Mode
D1 Models: NO; D2 Models: NC
E2EZ-X4D Protection Circuits
Load short-circuit protection, Surge suppressor
E2EZ-X4D Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EZ-X4D Response Frequency
E2EZ-X4D Sensing Distance
E2EZ-X4D Standard Sensing Object
E2EZ-X8B1 Current Consumption
E2EZ-X8B1 Indicators
Detection indicator (red)
E2EZ-X8B1 Leakage Current
E2EZ-X8B1 Load Current
100mA max. at 12 VDC (30 VDC max.) and 200mA max. at 24 VDC (30 VDC max.)
E2EZ-X8B1 Operation Mode
NO (with sensing object approaching)
E2EZ-X8B1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2EZ-X8B1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2EZ-X8B1 Response Frequency
E2EZ-X8B1 Sensing Distance
E2EZ-X8B1 Standard Sensing Object
E2EZ-X8C1 Current Consumption
E2EZ-X8C1 Indicators
Detection indicator (red)
E2EZ-X8C1 Leakage Current
E2EZ-X8C1 Load Current
100mA max. at 12 VDC (30 VDC max.) and 200mA max. at 24 VDC (30 VDC max.)
E2EZ-X8C1 Operation Mode
NO (with sensing object approaching)
E2EZ-X8C1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2EZ-X8C1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2EZ-X8C1 Response Frequency
E2EZ-X8C1 Sensing Distance
E2EZ-X8C1 Standard Sensing Object
E2EZ-X8D Current Consumption
E2EZ-X8D Indicators
D1 Models: Operation indicator (red), Setting indicator (green); D2 Models: Operation indicator (red)
E2EZ-X8D Operation Mode
D1 Models: NO; D2 Models: NC
E2EZ-X8D Protection Circuits
Load short-circuit protection, Surge suppressor
E2EZ-X8D Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EZ-X8D Response Frequency
E2EZ-X8D Sensing Distance
E2EZ-X8D Standard Sensing Object
Power Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Temperature Influence
±20% max. of sensing distance at 23°C in the temperature range of 0 to 50°C
Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range