E2K-C20MC1 Accessories
Mounting Bracket, M4 screws, Instruction manual
E2K-C20MC1 Ambient Humidity Range
35% to 95% (with no condensation)
E2K-C20MC1 Ambient Temperature Range Max
E2K-C20MC1 Ambient Temperature Range Min
E2K-C20MC1 Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-C20MC1 Control Output Load Current
E2K-C20MC1 Control Output Residual Voltage
E2K-C20MC1 Current Consumption (AT 24 VDC)
E2K-C20MC1 Degree Of Protection
E2K-C20MC1 Detectable Object
Conductors and dielectrics
E2K-C20MC1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min
E2K-C20MC1 Differential Travel
15% max. of sensing distance
E2K-C20MC1 Indicators
Operation indicator (yellow)
E2K-C20MC1 Insulation Resistance
E2K-C20MC1 Power Supply Voltage
12 to 24 VDC (10 to 30 VDC)
E2K-C20MC1 Protection Circuits
Reverse polarity protection, Load short-circuit protection
E2K-C20MC1 Response Frequency
E2K-C20MC1 Sensing Distance
E2K-C20MC1 Sensing Distance Adjustable Range
E2K-C20MC1 Sensing Surface Material
E2K-C20MC1 Shock Resistance
500 m/s² 10 times each in X, Y, Z directions
E2K-C20MC1 Standard Sensing Object
Grounded metal plate: 50 × 50 × 1 mm
E2K-C20MC1 Temperature Influence
±15% max. at 23°C in -10 to 55°C range; ±25% max. at 23°C in -25 to 70°C range
E2K-C20MC1 Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, Z directions
E2K-C20MC1 Voltage Influence
±2% max. of sensing distance at rated voltage
E2K-C20MT1 Accessories
Mounting Bracket, M4 screws, Instruction manual
E2K-C20MT1 Ambient Humidity Range
35% to 95% (with no condensation)
E2K-C20MT1 Ambient Temperature Range Max
E2K-C20MT1 Ambient Temperature Range Min
E2K-C20MT1 Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-C20MT1 Control Output Load Current
5 to 200mA (resistive load)
E2K-C20MT1 Control Output Residual Voltage
AC power: 10V max., DC power: 8V max.
E2K-C20MT1 Degree Of Protection
E2K-C20MT1 Detectable Object
Conductors and dielectrics
E2K-C20MT1 Dielectric Strength
1,500 VAC, 50/60Hz for 1 min
E2K-C20MT1 Differential Travel
15% max. of sensing distance
E2K-C20MT1 Indicators
Operation indicator (yellow)
E2K-C20MT1 Insulation Resistance
E2K-C20MT1 Power Supply Voltage
24 to 240 VAC (20 to 250 VAC); 24 to 240 VDC (20 to 250 VDC)
E2K-C20MT1 Response Frequency
E2K-C20MT1 Sensing Distance
E2K-C20MT1 Sensing Distance Adjustable Range
E2K-C20MT1 Sensing Surface Material
E2K-C20MT1 Shock Resistance
500 m/s² 10 times each in X, Y, Z directions
E2K-C20MT1 Standard Sensing Object
Grounded metal plate: 50 × 50 × 1 mm
E2K-C20MT1 Temperature Influence
±15% max. at 23°C in -10 to 55°C range; ±25% max. at 23°C in -25 to 70°C range
E2K-C20MT1 Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, Z directions
E2K-C20MT1 Voltage Influence
±2% max. of sensing distance at rated voltage
E2K-C25ME1 Accessories
Mounting Bracket, M4 screws, Instruction manual
E2K-C25ME1 Ambient Humidity Range
35% to 95% (with no condensation)
E2K-C25ME1 Ambient Temperature Range Max
E2K-C25ME1 Ambient Temperature Range Min
E2K-C25ME1 Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-C25ME1 Control Output Load Current
E2K-C25ME1 Control Output Residual Voltage
E2K-C25ME1 Current Consumption
10mA max at 12 VDC, 16mA max at 24 VDC
E2K-C25ME1 Degree Of Protection
E2K-C25ME1 Detectable Object
Conductors and dielectrics
E2K-C25ME1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min
E2K-C25ME1 Differential Travel
15% max. of sensing distance
E2K-C25ME1 Indicators
Detection indicator (red)
E2K-C25ME1 Insulation Resistance
E2K-C25ME1 Power Supply Voltage
12 to 24 VDC (10 to 30 VDC)
E2K-C25ME1 Protection Circuits
Reverse polarity protection, Surge suppressor
E2K-C25ME1 Response Frequency
E2K-C25ME1 Sensing Distance
E2K-C25ME1 Sensing Distance Adjustable Range
E2K-C25ME1 Sensing Surface Material
E2K-C25ME1 Shock Resistance
500 m/s² 10 times each in X, Y, Z directions
E2K-C25ME1 Standard Sensing Object
Grounded metal plate: 50 × 50 × 1 mm
E2K-C25ME1 Temperature Influence
±15% max. at 23°C in -10 to 55°C range; ±25% max. at 23°C in -25 to 70°C range
E2K-C25ME1 Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, Z directions
E2K-C25ME1 Voltage Influence
±2% max. of sensing distance at rated voltage
E2K-C25MY1 Accessories
Mounting Bracket, M4 screws, Instruction manual
E2K-C25MY1 Ambient Humidity Range
35% to 95% (with no condensation)
E2K-C25MY1 Ambient Temperature Range Max
E2K-C25MY1 Ambient Temperature Range Min
E2K-C25MY1 Connection Method
Pre-wired Models (Standard cable length: 2 m)
E2K-C25MY1 Control Output Load Current
E2K-C25MY1 Control Output Residual Voltage
E2K-C25MY1 Current Consumption
1mA max at 100 VAC, 2mA max at 200 VAC
E2K-C25MY1 Degree Of Protection
E2K-C25MY1 Detectable Object
Conductors and dielectrics
E2K-C25MY1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min
E2K-C25MY1 Differential Travel
15% max. of sensing distance
E2K-C25MY1 Indicators
Operation indicator (red)
E2K-C25MY1 Insulation Resistance
E2K-C25MY1 Power Supply Voltage
100 to 220 VAC (90 to 250 VAC)
E2K-C25MY1 Protection Circuits
E2K-C25MY1 Response Frequency
E2K-C25MY1 Sensing Distance
E2K-C25MY1 Sensing Distance Adjustable Range
E2K-C25MY1 Sensing Surface Material
E2K-C25MY1 Shock Resistance
500 m/s² 10 times each in X, Y, Z directions
E2K-C25MY1 Standard Sensing Object
Grounded metal plate: 50 × 50 × 1 mm
E2K-C25MY1 Temperature Influence
±15% max. at 23°C in -10 to 55°C range; ±25% max. at 23°C in -25 to 70°C range
E2K-C25MY1 Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, Z directions
E2K-C25MY1 Voltage Influence
±2% max. of sensing distance at rated voltage