Part No:
BR246-20A1-6V
Category:Relays, Contactors & Solenoids
Description:Relays, 10 Amp, 2PDT
Package:-
Production Status:
In Stock Status:
Products Detail
BR246 series relays are 10 Amp miniature non-latching 2 pole, double throw, dry circuit switching, hermetically sealed, all welded corrosion resistance case. This relay series offers 2 set of normally open and closed contacts, with magnetically driven actuation designed, built and qualified to MIL-PRF-83536, with relatively long life of 100,000 cycles at rated current, and 400,000 cycles mechanical life(contacts opening and closing).The relay operates when the coil is energized, current flows through the coil wires inducing a magnetic field, actuation is achieved when contacts that are attached to armature a ferrous metal plate is attracted and pivots when acted upon by the energized coil magnetic field closing or opening the relay contacts.
Coil voltages : 6, 12, 28, 48DC, or 115VAC 50-400Hz
Contact arrangment: 2PDT
Pull In Power: 500 mw
Contact Resistance : 0.010 Ohms
Insulation Resistance : 100 M-ohms @ 500 VDC
Dielectric contact to case, contact to contact, across open contacts: 1250 VRMS
Dielectric strength coil to case : 1000 VRMS
Dielectric strength all points at 80,000 feet : 350 VRMS
Vibration Sine: 10-3000Hz 30 Gs
Vibration Random: 0.4 g²/Hz, 50 to 2000Hz
Shock : 200G’s 6 mS
Acceleration: 15 Gs
Temperature Range. : -70 °C to +125 °C
Size: 1.05" X 1.05" X .525"
Weight : 1.6 oz approx.
Operate/Release time at room temperature: DC coil 15 ms max, AC coil 50 ms max
Contact bounce at room temperature: 1 ms at rated contact load, 28VDC
Rupture: 50 Amps @28VDC, 80 Amps @ 115AC 400 Hz
Overload: 40 Amp @28VDC, 60 Amp @115AC 400Hz
Time current : upto 350 Amps
Contact rating- Resistive @ 28VDC or 115/200VAC, 400 Hz: 10 Amp, Life=100K Cycles
Contact rating-Inductive @ 28VDC or 115/200VAC, 400 Hz: 8 Amp, Life=20K Cycles
Contact rating-Motor @ 28VDC or 115/200VAC, 400 Hz: 4 Amp, Life=100K Cycles
Contact rating-Lamp @ 28VDC or 115/200VAC, 400 Hz: 2 Amp, Life=100K Cycles
Contact rating- Resistive @ 115/200VAC, 60 Hz: 2.5 Amp, Life=10K Cycles
Contact rating-Inductive @ 115/200VAC, 60 Hz: 2.5 Amp, Life=10K Cycles
Contact rating-Motor @ 115/200VAC, 60 Hz: 2 Amp, Life=10K Cycles
Contact rating-Lamp @ 115/200VAC, 60 Hz: 1 Amp, Life=10K CyclesKey Features
No key features available
Application scenarios
No application scenarios available
Documents