Insulation Resistance
50MΩ min. (at 500 VDC) between the case and current carry parts
Degree Of Protection
Sensor: IEC60529 IP67 (JEM IP67g waterproof and oil-proof)
Ambient Humidity
Operating: 35% to 95% (Sensor) and 35% to 85% (Amplifier)
Vibration Resistance
Sensor: 10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, Z; Amplifier: 10 to 25Hz, 2-mm double amplitude for 2 hours each in X, Y, Z
Shock Resistance
Sensor: 500 m/s² (approx. 50G) 3 times each in X, Y, Z; Amplifier: 100 m/s² (approx. 10G) 3 times each in X, Y, Z
Ambient Temperature
Operating: -25°C to 70°C (Sensor) and -10°C to 55°C (Amplifier) with no icing
Cord Length
Sensor: 2-conductor, 3-m-long (standard length) or 5-m-long shielded cord
Cord Length Compensation
3 or 5 m (selectable with selector on front panel)
E2CA-AL4C Current Consumption
E2CA-AL4C Dielectric Strength
1,000 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AL4C Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2CA-AL4C Voltage Influence
±0.5% FS max. of linear output current at a voltage between 80% and 120% of the rated power supply voltage
E2CA-AL4C Weight Amplifier
E2CA-AL4D Current Consumption
E2CA-AL4D Dielectric Strength
1,000 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AL4D Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2CA-AL4D Voltage Influence
±0.5% FS max. of linear output current at a voltage between 80% and 120% of the rated power supply voltage
E2CA-AL4D Weight Amplifier
E2CA-AL4E Current Consumption
E2CA-AL4E Dielectric Strength
1,000 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AL4E Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2CA-AL4E Voltage Influence
±0.5% FS max. of linear output current at a voltage between 80% and 120% of the rated power supply voltage
E2CA-AL4E Weight Amplifier
E2CA-AL4F Current Consumption
E2CA-AL4F Dielectric Strength
1,000 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AL4F Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2CA-AL4F Voltage Influence
±0.5% FS max. of linear output current at a voltage between 80% and 120% of the rated power supply voltage
E2CA-AL4F Weight Amplifier
E2CA-AN4C Current Consumption
E2CA-AN4C Dielectric Strength
1,500 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AN4C Supply Voltage
100 to 240 VAC 50/60Hz (90 to 264 VAC)
E2CA-AN4C Voltage Influence
±0.5% FS max. of linear output current at a voltage between 90% and 110% of the rated power supply voltage
E2CA-AN4C Weight Amplifier
E2CA-AN4D Current Consumption
E2CA-AN4D Dielectric Strength
1,500 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AN4D Supply Voltage
100 to 240 VAC 50/60Hz (90 to 264 VAC)
E2CA-AN4D Voltage Influence
±0.5% FS max. of linear output current at a voltage between 90% and 110% of the rated power supply voltage
E2CA-AN4D Weight Amplifier
E2CA-AN4E Current Consumption
E2CA-AN4E Dielectric Strength
1,500 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AN4E Supply Voltage
100 to 240 VAC 50/60Hz (90 to 264 VAC)
E2CA-AN4E Voltage Influence
±0.5% FS max. of linear output current at a voltage between 90% and 110% of the rated power supply voltage
E2CA-AN4E Weight Amplifier
E2CA-AN4F Current Consumption
E2CA-AN4F Dielectric Strength
1,500 VAC (50/60Hz) for 1 min between current carry parts and case
E2CA-AN4F Supply Voltage
100 to 240 VAC 50/60Hz (90 to 264 VAC)
E2CA-AN4F Voltage Influence
±0.5% FS max. of linear output current at a voltage between 90% and 110% of the rated power supply voltage
E2CA-AN4F Weight Amplifier
E2CA-X10A Response Frequency Linear
E2CA-X10A Response Frequency Switching
E2CA-X10A Sensing Range
2 to 10 mm (30 x 30 x 1 mm iron)
E2CA-X10A Temperature Influence
±10% FS max. of sensing distance at 23°C in the rated ambient operating temperature range of -10°C and 40°C
E2CA-X2A Response Frequency Linear
E2CA-X2A Response Frequency Switching
E2CA-X2A Sensing Range
0.4 to 2 mm (12 x 12 x 1 mm iron)
E2CA-X2A Temperature Influence
±10% FS max. of linear output current at 23°C in the rated ambient operating temperature range of the Sensor and Amplifier Units
E2CA-X5A Response Frequency Linear
E2CA-X5A Response Frequency Switching
E2CA-X5A Sensing Range
1 to 5 mm (18 x 18 x 1 mm iron)
E2CA-X5A Temperature Influence
±10% FS max. of sensing distance at 23°C in the rated ambient operating temperature range of -10°C and 40°C
E2CA-XIR5A Response Frequency Linear
E2CA-XIR5A Response Frequency Switching
E2CA-XIR5A Sensing Range
0.3 to 1.5 mm (8 x 8 x 1 mm iron)
E2CA-XIR5A Temperature Influence
±10% FS max. of linear output current at 23°C in the rated ambient operating temperature range of the Sensor and Amplifier Units
Indicators
POWER, SPAN (linear range), and OPER (switching output) indicators
Linear Output
4 to 20mA (with permissible load resistance of 0 to 300Ω)
Switching Output
100mA max. transistor photocoupler output at 40 VDC with max. residual voltage of 2V
Switching Output Mode
Normally open or normally closed (selectable with selector on front panel)