Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric Strength
1,000 VAC for 1 min between current-carrying parts and case
Degree Of Protection
IEC 60529 IP67, in-house standards: oil-resistant
Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Ambient Humidity Range
Operating/Storage: 35% to 95% (with no condensation)
Detectable Object
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
E2EQ-X10D1 Ambient Temperature Range Operating
E2EQ-X10D1 Ambient Temperature Range Storage
E2EQ-X10D1 Connection Method
E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m); E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm)
E2EQ-X10D1 Control Output Load Current
E2EQ-X10D1 Control Output Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X10D1 Differential Travel
10% max. of sensing distance
E2EQ-X10D1 Operation Mode
E2EQ-X10D1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X10D1 Response Frequency
E2EQ-X10D1 Sensing Distance
E2EQ-X10D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X10D1 Standard Sensing Object
E2EQ-X10D1 Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
E2EQ-X10D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X10D1 Weight Pre-wired Connector Models
E2EQ-X10D1 Weight Pre-wired Models
E2EQ-X15X1 Ambient Temperature Range Operating
E2EQ-X15X1 Ambient Temperature Range Storage
E2EQ-X15X1 Connection Method
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
E2EQ-X15X1 Control Output Load Current
E2EQ-X15X1 Control Output Residual Voltage
5V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X15X1 Differential Travel
15% max. of sensing distance
E2EQ-X15X1 Operation Mode
E2EQ-X15X1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X15X1 Response Frequency
E2EQ-X15X1 Sensing Distance
E2EQ-X15X1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X15X1 Standard Sensing Object
E2EQ-X15X1 Temperature Influence
±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C
E2EQ-X15X1 Voltage Influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X15X1 Weight Pre-wired Connector Models
E2EQ-X15X1 Weight Pre-wired Models
E2EQ-X3D1 Ambient Temperature Range Operating
E2EQ-X3D1 Ambient Temperature Range Storage
E2EQ-X3D1 Connection Method
E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m); E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm)
E2EQ-X3D1 Control Output Load Current
E2EQ-X3D1 Control Output Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X3D1 Differential Travel
10% max. of sensing distance
E2EQ-X3D1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X3D1 Response Frequency
E2EQ-X3D1 Sensing Distance
E2EQ-X3D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X3D1 Standard Sensing Object
E2EQ-X3D1 Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
E2EQ-X3D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X3D1 Weight Pre-wired Connector Models
E2EQ-X3D1 Weight Pre-wired Models
E2EQ-X4X1 Ambient Temperature Range Operating
E2EQ-X4X1 Ambient Temperature Range Storage
E2EQ-X4X1 Connection Method
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
E2EQ-X4X1 Control Output Load Current
E2EQ-X4X1 Control Output Residual Voltage
5V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X4X1 Differential Travel
15% max. of sensing distance
E2EQ-X4X1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X4X1 Response Frequency
E2EQ-X4X1 Sensing Distance
E2EQ-X4X1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X4X1 Standard Sensing Object
E2EQ-X4X1 Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
E2EQ-X4X1 Voltage Influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X4X1 Weight Pre-wired Connector Models
E2EQ-X4X1 Weight Pre-wired Models
E2EQ-X7D1 Ambient Temperature Range Operating
E2EQ-X7D1 Ambient Temperature Range Storage
E2EQ-X7D1 Connection Method
E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m); E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm)
E2EQ-X7D1 Control Output Load Current
E2EQ-X7D1 Control Output Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X7D1 Differential Travel
10% max. of sensing distance
E2EQ-X7D1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X7D1 Response Frequency
E2EQ-X7D1 Sensing Distance
E2EQ-X7D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X7D1 Standard Sensing Object
E2EQ-X7D1 Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
E2EQ-X7D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X7D1 Weight Pre-wired Connector Models
E2EQ-X7D1 Weight Pre-wired Models
E2EQ-X8X1 Ambient Temperature Range Operating
E2EQ-X8X1 Ambient Temperature Range Storage
E2EQ-X8X1 Connection Method
Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models
E2EQ-X8X1 Control Output Load Current
E2EQ-X8X1 Control Output Residual Voltage
5V max. (Load current: 100mA, Cable length: 2 m)
E2EQ-X8X1 Differential Travel
15% max. of sensing distance
E2EQ-X8X1 Protection Circuits
Load short-circuit protection, Surge suppressor
E2EQ-X8X1 Response Frequency
E2EQ-X8X1 Sensing Distance
E2EQ-X8X1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2EQ-X8X1 Standard Sensing Object
E2EQ-X8X1 Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C
E2EQ-X8X1 Voltage Influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2EQ-X8X1 Weight Pre-wired Connector Models
E2EQ-X8X1 Weight Pre-wired Models
Indicators
Operation indicator (red), Setting indicator (green)
Materials Case
Fluororesin coating (Base material: brass)
Materials Clamping Nuts
Fluororesin coating (Base material: brass)
Materials Sensing Surface
Power Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.