Insulation Resistance
50MΩ min. (at 500 VDC) between current-carrying parts and case
Vibration Resistance
10 to 55Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Ambient Humidity Range Max
Ambient Humidity Range Min
Ambient Temperature Range
E2FQ-X10@ Mounting Hole Diameter
E2FQ-X10D1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X10D1 Indicators
Operation indicator (red), Setting indicator (green)
E2FQ-X10D1 Leakage Current
E2FQ-X10D1 Power Supply Voltage
12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
E2FQ-X10D1 Protection Circuits
E2FQ-X10D1 Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2FQ-X10D1 Response Frequency
E2FQ-X10D1 Sensing Distance
E2FQ-X10D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X10D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
E2FQ-X10E1 Current Consumption
E2FQ-X10E1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X10E1 Indicators
Detection indicator (red)
E2FQ-X10E1 Power Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2FQ-X10E1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2FQ-X10E1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2FQ-X10E1 Response Frequency
E2FQ-X10E1 Sensing Distance
E2FQ-X10E1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X10E1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2FQ-X10Y1 Dielectric Strength
4,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X10Y1 Indicators
Operation indicator (red)
E2FQ-X10Y1 Leakage Current
E2FQ-X10Y1 Power Supply Voltage
24 to 240 VAC (20 to 264 VAC), 50/60Hz
E2FQ-X10Y1 Protection Circuits
E2FQ-X10Y1 Response Frequency
E2FQ-X10Y1 Sensing Distance
E2FQ-X10Y1 Shock Resistance
500 m/s² 10 times each in X, Y, and Z directions
E2FQ-X10Y1 Voltage Influence
±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
E2FQ-X2@ Mounting Hole Diameter
E2FQ-X2D1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X2D1 Indicators
Operation indicator (red), Setting indicator (green)
E2FQ-X2D1 Leakage Current
E2FQ-X2D1 Power Supply Voltage
12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
E2FQ-X2D1 Protection Circuits
E2FQ-X2D1 Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2FQ-X2D1 Response Frequency
E2FQ-X2D1 Sensing Distance
E2FQ-X2D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X2D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
E2FQ-X2E1 Current Consumption
E2FQ-X2E1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X2E1 Indicators
Detection indicator (red)
E2FQ-X2E1 Power Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2FQ-X2E1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2FQ-X2E1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2FQ-X2E1 Response Frequency
E2FQ-X2E1 Sensing Distance
E2FQ-X2E1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X2E1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2FQ-X5@ Mounting Hole Diameter
E2FQ-X5D1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X5D1 Indicators
Operation indicator (red), Setting indicator (green)
E2FQ-X5D1 Leakage Current
E2FQ-X5D1 Power Supply Voltage
12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
E2FQ-X5D1 Protection Circuits
E2FQ-X5D1 Residual Voltage
3V max. (Load current: 100mA, Cable length: 2 m)
E2FQ-X5D1 Response Frequency
E2FQ-X5D1 Sensing Distance
E2FQ-X5D1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X5D1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
E2FQ-X5E1 Current Consumption
E2FQ-X5E1 Dielectric Strength
1,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X5E1 Indicators
Detection indicator (red)
E2FQ-X5E1 Power Supply Voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
E2FQ-X5E1 Protection Circuits
Load short-circuit protection, Reverse polarity protection, Surge suppressor
E2FQ-X5E1 Residual Voltage
2V max. (Load current: 200mA, Cable length: 2 m)
E2FQ-X5E1 Response Frequency
E2FQ-X5E1 Sensing Distance
E2FQ-X5E1 Shock Resistance
1,000 m/s² 10 times each in X, Y, and Z directions
E2FQ-X5E1 Voltage Influence
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
E2FQ-X5Y1 Dielectric Strength
4,000 VAC, 50/60Hz for 1 min between current-carrying parts and case
E2FQ-X5Y1 Indicators
Operation indicator (red)
E2FQ-X5Y1 Leakage Current
E2FQ-X5Y1 Power Supply Voltage
24 to 240 VAC (20 to 264 VAC), 50/60Hz
E2FQ-X5Y1 Protection Circuits
E2FQ-X5Y1 Response Frequency
E2FQ-X5Y1 Sensing Distance
E2FQ-X5Y1 Shock Resistance
500 m/s² 10 times each in X, Y, and Z directions
E2FQ-X5Y1 Voltage Influence
±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Materials Sensing Surface
Temperature Influence
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C